IMS DB – User (System) Abend Codes

In IMS database you will receive user abend codes or system abends. This helps you you to fix your errors in your coding and you can provide better solution.

0002
Explanation:
When the IMS control region abnormally terminates, it forces this abend for active dependent regions. This abend can also occur after normal shutdown of the control region if a new dependent region attempts to start.

System action:
The dependent regions are abnormally terminated.

System Operator Response: Follow IMS restart procedures.

Problem determination:
 None.

0005
Explanation:
IMS restart was unable to close (terminate) the input online log data set (OLDS). Refer to messages DFS0738I and DFS0738X for further explanation.

System action:
 IMS terminates abnormally.

Programmer response:
 Use the Log Recovery utility to close (terminate) the log.

Problem determination:
 1, 5, 8, 11, 35, 40

Save a copy of the OLDSs and WADSs data sets.

006
Explanation:
The License Manager did not find a certificate for either the DB or the TM feature. See message DFS2930I to determine which (or both features) do not have a certificate.

System action:
 The region that issued the abend terminates.

Programmer response:
 Add the necessary certificates to LM or change the LM mode so that it grants requests even when certificates do not exist.

Module:
 DFSXSTM0

0008
Explanation:
The amount of storage specified for the region is insufficient to build TABLE zzzzzzzz. This prevents IMS from acquiring the information needed for initialization. Message DFS0610W, issued before this abend, identifies the TABLE name and provides additional information.

System action:
 IMS terminates abnormally.

Programmer response:
 Increase the size of the region.

Master Terminal Operator Response: Increase the size of the region, and retry IMS.

Problem determination:
 1, 3, 6, 8

0009
Explanation:
The OPEN failed for a data set. This prevents IMS from acquiring information required for initialization. Message DFS0597W, issued before this abend, identifies DDNAME xxxxxxxx and provides additional information.

System action:
 IMS terminates abnormally.

Programmer response:
 Refer to DFS0597I. Check the DDNAME xxxxxxxx data set.

Problem determination:
 1, 3, 6, 8

0010
Explanation:
The data set cannot be processed because the data set record format is not valid. This prevents IMS from acquiring information required for initialization. Message DFS0604W, issued before this abend, identifies DDNAME xxxxxxxx and provides additional information.

System action:
 IMS terminates abnormally.

Programmer response:
 Refer to message DFS0604W. Be sure the DDNAME xxxxxxxx data set has RECFM=F or RECFM=FB.

Problem determination:
 1, 3, 6, 8

More: Download IMS database User and System Abend codes

Advertisements

Author: Srini

Experienced software developer. Skills in Development, Coding, Testing and Debugging. Good Data analytic skills (Data Warehousing and BI). Also skills in Mainframe.